2 # Block device driver configuration
6 bool "Multiple devices driver support (RAID and LVM)"
9 Support multiple physical spindles through a single logical device.
10 Required for RAID and logical volume management.
15 tristate "RAID support"
17 This driver lets you combine several hard disk partitions into one
18 logical block device. This can be used to simply append one
19 partition to another one or to combine several redundant hard disks
20 into a RAID1/4/5 device so as to provide protection against hard
21 disk failures. This is called "Software RAID" since the combining of
22 the partitions is done by the kernel. "Hardware RAID" means that the
23 combining is done by a dedicated controller; if you have such a
24 controller, you do not need to say Y here.
26 More information about Software RAID on Linux is contained in the
27 Software RAID mini-HOWTO, available from
28 <http://www.tldp.org/docs.html#howto>. There you will also learn
29 where to get the supporting user space utilities raidtools.
34 bool "Autodetect RAID arrays during kernel boot"
35 depends on BLK_DEV_MD=y
38 If you say Y here, then the kernel will try to autodetect raid
39 arrays as part of its boot process.
41 If you don't use raid and say Y, this autodetection can cause
42 a several-second delay in the boot time due to various
43 synchronisation steps that are part of this step.
48 tristate "Linear (append) mode"
51 If you say Y here, then your multiple devices driver will be able to
52 use the so-called linear mode, i.e. it will combine the hard disk
53 partitions by simply appending one to the other.
55 To compile this as a module, choose M here: the module
56 will be called linear.
61 tristate "RAID-0 (striping) mode"
64 If you say Y here, then your multiple devices driver will be able to
65 use the so-called raid0 mode, i.e. it will combine the hard disk
66 partitions into one logical device in such a fashion as to fill them
67 up evenly, one chunk here and one chunk there. This will increase
68 the throughput rate if the partitions reside on distinct disks.
70 Information about Software RAID on Linux is contained in the
71 Software-RAID mini-HOWTO, available from
72 <http://www.tldp.org/docs.html#howto>. There you will also
73 learn where to get the supporting user space utilities raidtools.
75 To compile this as a module, choose M here: the module
81 tristate "RAID-1 (mirroring) mode"
84 A RAID-1 set consists of several disk drives which are exact copies
85 of each other. In the event of a mirror failure, the RAID driver
86 will continue to use the operational mirrors in the set, providing
87 an error free MD (multiple device) to the higher levels of the
88 kernel. In a set with N drives, the available space is the capacity
89 of a single drive, and the set protects against a failure of (N - 1)
92 Information about Software RAID on Linux is contained in the
93 Software-RAID mini-HOWTO, available from
94 <http://www.tldp.org/docs.html#howto>. There you will also
95 learn where to get the supporting user space utilities raidtools.
97 If you want to use such a RAID-1 set, say Y. To compile this code
98 as a module, choose M here: the module will be called raid1.
103 tristate "RAID-10 (mirrored striping) mode"
104 depends on BLK_DEV_MD
106 RAID-10 provides a combination of striping (RAID-0) and
107 mirroring (RAID-1) with easier configuration and more flexible
109 Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
110 be the same size (or at least, only as much as the smallest device
112 RAID-10 provides a variety of layouts that provide different levels
113 of redundancy and performance.
115 RAID-10 requires mdadm-1.7.0 or later, available at:
117 ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
122 tristate "RAID-4/RAID-5/RAID-6 mode"
123 depends on BLK_DEV_MD
128 select ASYNC_RAID6_RECOV
130 A RAID-5 set of N drives with a capacity of C MB per drive provides
131 the capacity of C * (N - 1) MB, and protects against a failure
132 of a single drive. For a given sector (row) number, (N - 1) drives
133 contain data sectors, and one drive contains the parity protection.
134 For a RAID-4 set, the parity blocks are present on a single drive,
135 while a RAID-5 set distributes the parity across the drives in one
136 of the available parity distribution methods.
138 A RAID-6 set of N drives with a capacity of C MB per drive
139 provides the capacity of C * (N - 2) MB, and protects
140 against a failure of any two drives. For a given sector
141 (row) number, (N - 2) drives contain data sectors, and two
142 drives contains two independent redundancy syndromes. Like
143 RAID-5, RAID-6 distributes the syndromes across the drives
144 in one of the available parity distribution methods.
146 Information about Software RAID on Linux is contained in the
147 Software-RAID mini-HOWTO, available from
148 <http://www.tldp.org/docs.html#howto>. There you will also
149 learn where to get the supporting user space utilities raidtools.
151 If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y. To
152 compile this code as a module, choose M here: the module
153 will be called raid456.
158 tristate "Multipath I/O support"
159 depends on BLK_DEV_MD
161 MD_MULTIPATH provides a simple multi-path personality for use
162 the MD framework. It is not under active development. New
163 projects should consider using DM_MULTIPATH which has more
164 features and more testing.
169 tristate "Faulty test module for MD"
170 depends on BLK_DEV_MD
172 The "faulty" module allows for a block device that occasionally returns
173 read or write errors. It is useful for testing.
177 source "drivers/md/bcache/Kconfig"
180 tristate "Device mapper support"
182 Device-mapper is a low level volume manager. It works by allowing
183 people to specify mappings for ranges of logical sectors. Various
184 mapping types are available, in addition people may write their own
185 modules containing custom mappings if they wish.
187 Higher level volume managers such as LVM2 use this driver.
189 To compile this as a module, choose M here: the module will be
195 boolean "Device mapper debugging support"
196 depends on BLK_DEV_DM
198 Enable this for messages that may help debug device-mapper problems.
204 depends on BLK_DEV_DM
206 This interface allows you to do buffered I/O on a device and acts
207 as a cache, holding recently-read blocks in memory and performing
212 depends on BLK_DEV_DM
214 Some bio locking schemes used by other device-mapper targets
215 including thin provisioning.
217 source "drivers/md/persistent-data/Kconfig"
220 tristate "Crypt target support"
221 depends on BLK_DEV_DM
225 This device-mapper target allows you to create a device that
226 transparently encrypts the data on it. You'll need to activate
227 the ciphers you're going to use in the cryptoapi configuration.
229 Information on how to use dm-crypt can be found on
231 <http://www.saout.de/misc/dm-crypt/>
233 To compile this code as a module, choose M here: the module will
239 tristate "Snapshot target"
240 depends on BLK_DEV_DM
242 Allow volume managers to take writable snapshots of a device.
244 config DM_THIN_PROVISIONING
245 tristate "Thin provisioning target"
246 depends on BLK_DEV_DM
247 select DM_PERSISTENT_DATA
250 Provides thin provisioning and snapshots that share a data store.
252 config DM_DEBUG_BLOCK_STACK_TRACING
253 boolean "Keep stack trace of thin provisioning block lock holders"
254 depends on STACKTRACE_SUPPORT && DM_THIN_PROVISIONING
257 Enable this for messages that may help debug problems with the
258 block manager locking used by thin provisioning.
263 tristate "Cache target (EXPERIMENTAL)"
264 depends on BLK_DEV_DM
266 select DM_PERSISTENT_DATA
269 dm-cache attempts to improve performance of a block device by
270 moving frequently used data to a smaller, higher performance
271 device. Different 'policy' plugins can be used to change the
272 algorithms used to select which blocks are promoted, demoted,
273 cleaned etc. It supports writeback and writethrough modes.
276 tristate "MQ Cache Policy (EXPERIMENTAL)"
280 A cache policy that uses a multiqueue ordered by recent hit
281 count to select which blocks should be promoted and demoted.
282 This is meant to be a general purpose policy. It prioritises
285 config DM_CACHE_CLEANER
286 tristate "Cleaner Cache Policy (EXPERIMENTAL)"
290 A simple cache policy that writes back all data to the
291 origin. Used when decommissioning a dm-cache.
294 tristate "Mirror target"
295 depends on BLK_DEV_DM
297 Allow volume managers to mirror logical volumes, also
298 needed for live data migration tools such as 'pvmove'.
301 tristate "RAID 1/4/5/6/10 target"
302 depends on BLK_DEV_DM
308 A dm target that supports RAID1, RAID10, RAID4, RAID5 and RAID6 mappings
310 A RAID-5 set of N drives with a capacity of C MB per drive provides
311 the capacity of C * (N - 1) MB, and protects against a failure
312 of a single drive. For a given sector (row) number, (N - 1) drives
313 contain data sectors, and one drive contains the parity protection.
314 For a RAID-4 set, the parity blocks are present on a single drive,
315 while a RAID-5 set distributes the parity across the drives in one
316 of the available parity distribution methods.
318 A RAID-6 set of N drives with a capacity of C MB per drive
319 provides the capacity of C * (N - 2) MB, and protects
320 against a failure of any two drives. For a given sector
321 (row) number, (N - 2) drives contain data sectors, and two
322 drives contains two independent redundancy syndromes. Like
323 RAID-5, RAID-6 distributes the syndromes across the drives
324 in one of the available parity distribution methods.
326 config DM_LOG_USERSPACE
327 tristate "Mirror userspace logging"
328 depends on DM_MIRROR && NET
331 The userspace logging module provides a mechanism for
332 relaying the dm-dirty-log API to userspace. Log designs
333 which are more suited to userspace implementation (e.g.
334 shared storage logs) or experimental logs can be implemented
335 by leveraging this framework.
338 tristate "Zero target"
339 depends on BLK_DEV_DM
341 A target that discards writes, and returns all zeroes for
342 reads. Useful in some recovery situations.
345 tristate "Multipath target"
346 depends on BLK_DEV_DM
347 # nasty syntax but means make DM_MULTIPATH independent
348 # of SCSI_DH if the latter isn't defined but if
349 # it is, DM_MULTIPATH must depend on it. We get a build
350 # error if SCSI_DH=m and DM_MULTIPATH=y
351 depends on SCSI_DH || !SCSI_DH
353 Allow volume managers to support multipath hardware.
355 config DM_MULTIPATH_QL
356 tristate "I/O Path Selector based on the number of in-flight I/Os"
357 depends on DM_MULTIPATH
359 This path selector is a dynamic load balancer which selects
360 the path with the least number of in-flight I/Os.
364 config DM_MULTIPATH_ST
365 tristate "I/O Path Selector based on the service time"
366 depends on DM_MULTIPATH
368 This path selector is a dynamic load balancer which selects
369 the path expected to complete the incoming I/O in the shortest
375 tristate "I/O delaying target"
376 depends on BLK_DEV_DM
378 A target that delays reads and/or writes and can send
379 them to different devices. Useful for testing.
385 depends on BLK_DEV_DM
387 Generate udev events for DM events.
390 tristate "Flakey target"
391 depends on BLK_DEV_DM
393 A target that intermittently fails I/O for debugging purposes.
396 tristate "Verity target support"
397 depends on BLK_DEV_DM
402 This device-mapper target creates a read-only device that
403 transparently validates the data on one underlying device against
404 a pre-generated tree of cryptographic checksums stored on a second
407 You'll need to activate the digests you're going to use in the
408 cryptoapi configuration.
410 To compile this code as a module, choose M here: the module will