bq20z75: Add optional battery detect gpio
[firefly-linux-kernel-4.4.55.git] / drivers / power / bq20z75.c
1 /*
2  * Gas Gauge driver for TI's BQ20Z75
3  *
4  * Copyright (c) 2010, NVIDIA Corporation.
5  *
6  * This program is free software; you can redistribute it and/or modify
7  * it under the terms of the GNU General Public License as published by
8  * the Free Software Foundation; either version 2 of the License, or
9  * (at your option) any later version.
10  *
11  * This program is distributed in the hope that it will be useful, but WITHOUT
12  * ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or
13  * FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public License for
14  * more details.
15  *
16  * You should have received a copy of the GNU General Public License along
17  * with this program; if not, write to the Free Software Foundation, Inc.,
18  * 51 Franklin Street, Fifth Floor, Boston, MA  02110-1301, USA.
19  */
20
21 #include <linux/init.h>
22 #include <linux/module.h>
23 #include <linux/kernel.h>
24 #include <linux/err.h>
25 #include <linux/power_supply.h>
26 #include <linux/i2c.h>
27 #include <linux/slab.h>
28 #include <linux/interrupt.h>
29 #include <linux/gpio.h>
30
31 #include <linux/power/bq20z75.h>
32
33 enum {
34         REG_MANUFACTURER_DATA,
35         REG_TEMPERATURE,
36         REG_VOLTAGE,
37         REG_CURRENT,
38         REG_CAPACITY,
39         REG_TIME_TO_EMPTY,
40         REG_TIME_TO_FULL,
41         REG_STATUS,
42         REG_CYCLE_COUNT,
43         REG_SERIAL_NUMBER,
44         REG_REMAINING_CAPACITY,
45         REG_REMAINING_CAPACITY_CHARGE,
46         REG_FULL_CHARGE_CAPACITY,
47         REG_FULL_CHARGE_CAPACITY_CHARGE,
48         REG_DESIGN_CAPACITY,
49         REG_DESIGN_CAPACITY_CHARGE,
50         REG_DESIGN_VOLTAGE,
51 };
52
53 /* Battery Mode defines */
54 #define BATTERY_MODE_OFFSET             0x03
55 #define BATTERY_MODE_MASK               0x8000
56 enum bq20z75_battery_mode {
57         BATTERY_MODE_AMPS,
58         BATTERY_MODE_WATTS
59 };
60
61 /* manufacturer access defines */
62 #define MANUFACTURER_ACCESS_STATUS      0x0006
63 #define MANUFACTURER_ACCESS_SLEEP       0x0011
64
65 /* battery status value bits */
66 #define BATTERY_DISCHARGING             0x40
67 #define BATTERY_FULL_CHARGED            0x20
68 #define BATTERY_FULL_DISCHARGED         0x10
69
70 #define BQ20Z75_DATA(_psp, _addr, _min_value, _max_value) { \
71         .psp = _psp, \
72         .addr = _addr, \
73         .min_value = _min_value, \
74         .max_value = _max_value, \
75 }
76
77 static const struct bq20z75_device_data {
78         enum power_supply_property psp;
79         u8 addr;
80         int min_value;
81         int max_value;
82 } bq20z75_data[] = {
83         [REG_MANUFACTURER_DATA] =
84                 BQ20Z75_DATA(POWER_SUPPLY_PROP_PRESENT, 0x00, 0, 65535),
85         [REG_TEMPERATURE] =
86                 BQ20Z75_DATA(POWER_SUPPLY_PROP_TEMP, 0x08, 0, 65535),
87         [REG_VOLTAGE] =
88                 BQ20Z75_DATA(POWER_SUPPLY_PROP_VOLTAGE_NOW, 0x09, 0, 20000),
89         [REG_CURRENT] =
90                 BQ20Z75_DATA(POWER_SUPPLY_PROP_CURRENT_NOW, 0x0A, -32768,
91                         32767),
92         [REG_CAPACITY] =
93                 BQ20Z75_DATA(POWER_SUPPLY_PROP_CAPACITY, 0x0E, 0, 100),
94         [REG_REMAINING_CAPACITY] =
95                 BQ20Z75_DATA(POWER_SUPPLY_PROP_ENERGY_NOW, 0x0F, 0, 65535),
96         [REG_REMAINING_CAPACITY_CHARGE] =
97                 BQ20Z75_DATA(POWER_SUPPLY_PROP_CHARGE_NOW, 0x0F, 0, 65535),
98         [REG_FULL_CHARGE_CAPACITY] =
99                 BQ20Z75_DATA(POWER_SUPPLY_PROP_ENERGY_FULL, 0x10, 0, 65535),
100         [REG_FULL_CHARGE_CAPACITY_CHARGE] =
101                 BQ20Z75_DATA(POWER_SUPPLY_PROP_CHARGE_FULL, 0x10, 0, 65535),
102         [REG_TIME_TO_EMPTY] =
103                 BQ20Z75_DATA(POWER_SUPPLY_PROP_TIME_TO_EMPTY_AVG, 0x12, 0,
104                         65535),
105         [REG_TIME_TO_FULL] =
106                 BQ20Z75_DATA(POWER_SUPPLY_PROP_TIME_TO_FULL_AVG, 0x13, 0,
107                         65535),
108         [REG_STATUS] =
109                 BQ20Z75_DATA(POWER_SUPPLY_PROP_STATUS, 0x16, 0, 65535),
110         [REG_CYCLE_COUNT] =
111                 BQ20Z75_DATA(POWER_SUPPLY_PROP_CYCLE_COUNT, 0x17, 0, 65535),
112         [REG_DESIGN_CAPACITY] =
113                 BQ20Z75_DATA(POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN, 0x18, 0,
114                         65535),
115         [REG_DESIGN_CAPACITY_CHARGE] =
116                 BQ20Z75_DATA(POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN, 0x18, 0,
117                         65535),
118         [REG_DESIGN_VOLTAGE] =
119                 BQ20Z75_DATA(POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN, 0x19, 0,
120                         65535),
121         [REG_SERIAL_NUMBER] =
122                 BQ20Z75_DATA(POWER_SUPPLY_PROP_SERIAL_NUMBER, 0x1C, 0, 65535),
123 };
124
125 static enum power_supply_property bq20z75_properties[] = {
126         POWER_SUPPLY_PROP_STATUS,
127         POWER_SUPPLY_PROP_HEALTH,
128         POWER_SUPPLY_PROP_PRESENT,
129         POWER_SUPPLY_PROP_TECHNOLOGY,
130         POWER_SUPPLY_PROP_CYCLE_COUNT,
131         POWER_SUPPLY_PROP_VOLTAGE_NOW,
132         POWER_SUPPLY_PROP_CURRENT_NOW,
133         POWER_SUPPLY_PROP_CAPACITY,
134         POWER_SUPPLY_PROP_TEMP,
135         POWER_SUPPLY_PROP_TIME_TO_EMPTY_AVG,
136         POWER_SUPPLY_PROP_TIME_TO_FULL_AVG,
137         POWER_SUPPLY_PROP_SERIAL_NUMBER,
138         POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN,
139         POWER_SUPPLY_PROP_ENERGY_NOW,
140         POWER_SUPPLY_PROP_ENERGY_FULL,
141         POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN,
142         POWER_SUPPLY_PROP_CHARGE_NOW,
143         POWER_SUPPLY_PROP_CHARGE_FULL,
144         POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
145 };
146
147 struct bq20z75_info {
148         struct i2c_client               *client;
149         struct power_supply             power_supply;
150         struct bq20z75_platform_data    *pdata;
151         bool                            is_present;
152         bool                            gpio_detect;
153         bool                            enable_detection;
154         int                             irq;
155 };
156
157 static int bq20z75_read_word_data(struct i2c_client *client, u8 address)
158 {
159         s32 ret;
160
161         ret = i2c_smbus_read_word_data(client, address);
162         if (ret < 0) {
163                 dev_err(&client->dev,
164                         "%s: i2c read at address 0x%x failed\n",
165                         __func__, address);
166                 return ret;
167         }
168         return le16_to_cpu(ret);
169 }
170
171 static int bq20z75_write_word_data(struct i2c_client *client, u8 address,
172         u16 value)
173 {
174         s32 ret;
175
176         ret = i2c_smbus_write_word_data(client, address, le16_to_cpu(value));
177         if (ret < 0) {
178                 dev_err(&client->dev,
179                         "%s: i2c write to address 0x%x failed\n",
180                         __func__, address);
181                 return ret;
182         }
183         return 0;
184 }
185
186 static int bq20z75_get_battery_presence_and_health(
187         struct i2c_client *client, enum power_supply_property psp,
188         union power_supply_propval *val)
189 {
190         s32 ret;
191         struct bq20z75_info *bq20z75_device = i2c_get_clientdata(client);
192
193         if (psp == POWER_SUPPLY_PROP_PRESENT &&
194                 bq20z75_device->gpio_detect) {
195                 ret = gpio_get_value(
196                         bq20z75_device->pdata->battery_detect);
197                 if (ret == bq20z75_device->pdata->battery_detect_present)
198                         val->intval = 1;
199                 else
200                         val->intval = 0;
201                 return ret;
202         }
203
204         /* Write to ManufacturerAccess with
205          * ManufacturerAccess command and then
206          * read the status */
207         ret = bq20z75_write_word_data(client,
208                 bq20z75_data[REG_MANUFACTURER_DATA].addr,
209                 MANUFACTURER_ACCESS_STATUS);
210         if (ret < 0)
211                 return ret;
212
213
214         ret = bq20z75_read_word_data(client,
215                 bq20z75_data[REG_MANUFACTURER_DATA].addr);
216         if (ret < 0) {
217                 if (psp == POWER_SUPPLY_PROP_PRESENT)
218                         val->intval = 0; /* battery removed */
219                 return ret;
220         }
221
222         if (ret < bq20z75_data[REG_MANUFACTURER_DATA].min_value ||
223             ret > bq20z75_data[REG_MANUFACTURER_DATA].max_value) {
224                 val->intval = 0;
225                 return 0;
226         }
227
228         /* Mask the upper nibble of 2nd byte and
229          * lower byte of response then
230          * shift the result by 8 to get status*/
231         ret &= 0x0F00;
232         ret >>= 8;
233         if (psp == POWER_SUPPLY_PROP_PRESENT) {
234                 if (ret == 0x0F)
235                         /* battery removed */
236                         val->intval = 0;
237                 else
238                         val->intval = 1;
239         } else if (psp == POWER_SUPPLY_PROP_HEALTH) {
240                 if (ret == 0x09)
241                         val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
242                 else if (ret == 0x0B)
243                         val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
244                 else if (ret == 0x0C)
245                         val->intval = POWER_SUPPLY_HEALTH_DEAD;
246                 else
247                         val->intval = POWER_SUPPLY_HEALTH_GOOD;
248         }
249
250         return 0;
251 }
252
253 static int bq20z75_get_battery_property(struct i2c_client *client,
254         int reg_offset, enum power_supply_property psp,
255         union power_supply_propval *val)
256 {
257         s32 ret;
258
259         ret = bq20z75_read_word_data(client,
260                 bq20z75_data[reg_offset].addr);
261         if (ret < 0)
262                 return ret;
263
264         /* returned values are 16 bit */
265         if (bq20z75_data[reg_offset].min_value < 0)
266                 ret = (s16)ret;
267
268         if (ret >= bq20z75_data[reg_offset].min_value &&
269             ret <= bq20z75_data[reg_offset].max_value) {
270                 val->intval = ret;
271                 if (psp == POWER_SUPPLY_PROP_STATUS) {
272                         if (ret & BATTERY_FULL_CHARGED)
273                                 val->intval = POWER_SUPPLY_STATUS_FULL;
274                         else if (ret & BATTERY_FULL_DISCHARGED)
275                                 val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
276                         else if (ret & BATTERY_DISCHARGING)
277                                 val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
278                         else
279                                 val->intval = POWER_SUPPLY_STATUS_CHARGING;
280                 }
281         } else {
282                 if (psp == POWER_SUPPLY_PROP_STATUS)
283                         val->intval = POWER_SUPPLY_STATUS_UNKNOWN;
284                 else
285                         val->intval = 0;
286         }
287
288         return 0;
289 }
290
291 static void  bq20z75_unit_adjustment(struct i2c_client *client,
292         enum power_supply_property psp, union power_supply_propval *val)
293 {
294 #define BASE_UNIT_CONVERSION            1000
295 #define BATTERY_MODE_CAP_MULT_WATT      (10 * BASE_UNIT_CONVERSION)
296 #define TIME_UNIT_CONVERSION            600
297 #define TEMP_KELVIN_TO_CELCIUS          2731
298         switch (psp) {
299         case POWER_SUPPLY_PROP_ENERGY_NOW:
300         case POWER_SUPPLY_PROP_ENERGY_FULL:
301         case POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN:
302                 val->intval *= BATTERY_MODE_CAP_MULT_WATT;
303                 break;
304
305         case POWER_SUPPLY_PROP_VOLTAGE_NOW:
306         case POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN:
307         case POWER_SUPPLY_PROP_CURRENT_NOW:
308         case POWER_SUPPLY_PROP_CHARGE_NOW:
309         case POWER_SUPPLY_PROP_CHARGE_FULL:
310         case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
311                 val->intval *= BASE_UNIT_CONVERSION;
312                 break;
313
314         case POWER_SUPPLY_PROP_TEMP:
315                 /* bq20z75 provides battery tempreture in 0.1°K
316                  * so convert it to 0.1°C */
317                 val->intval -= TEMP_KELVIN_TO_CELCIUS;
318                 val->intval *= 10;
319                 break;
320
321         case POWER_SUPPLY_PROP_TIME_TO_EMPTY_AVG:
322         case POWER_SUPPLY_PROP_TIME_TO_FULL_AVG:
323                 val->intval *= TIME_UNIT_CONVERSION;
324                 break;
325
326         default:
327                 dev_dbg(&client->dev,
328                         "%s: no need for unit conversion %d\n", __func__, psp);
329         }
330 }
331
332 static enum bq20z75_battery_mode
333 bq20z75_set_battery_mode(struct i2c_client *client,
334         enum bq20z75_battery_mode mode)
335 {
336         int ret, original_val;
337
338         original_val = bq20z75_read_word_data(client, BATTERY_MODE_OFFSET);
339         if (original_val < 0)
340                 return original_val;
341
342         if ((original_val & BATTERY_MODE_MASK) == mode)
343                 return mode;
344
345         if (mode == BATTERY_MODE_AMPS)
346                 ret = original_val & ~BATTERY_MODE_MASK;
347         else
348                 ret = original_val | BATTERY_MODE_MASK;
349
350         ret = bq20z75_write_word_data(client, BATTERY_MODE_OFFSET, ret);
351         if (ret < 0)
352                 return ret;
353
354         return original_val & BATTERY_MODE_MASK;
355 }
356
357 static int bq20z75_get_battery_capacity(struct i2c_client *client,
358         int reg_offset, enum power_supply_property psp,
359         union power_supply_propval *val)
360 {
361         s32 ret;
362         enum bq20z75_battery_mode mode = BATTERY_MODE_WATTS;
363
364         if (power_supply_is_amp_property(psp))
365                 mode = BATTERY_MODE_AMPS;
366
367         mode = bq20z75_set_battery_mode(client, mode);
368         if (mode < 0)
369                 return mode;
370
371         ret = bq20z75_read_word_data(client, bq20z75_data[reg_offset].addr);
372         if (ret < 0)
373                 return ret;
374
375         if (psp == POWER_SUPPLY_PROP_CAPACITY) {
376                 /* bq20z75 spec says that this can be >100 %
377                 * even if max value is 100 % */
378                 val->intval = min(ret, 100);
379         } else
380                 val->intval = ret;
381
382         ret = bq20z75_set_battery_mode(client, mode);
383         if (ret < 0)
384                 return ret;
385
386         return 0;
387 }
388
389 static char bq20z75_serial[5];
390 static int bq20z75_get_battery_serial_number(struct i2c_client *client,
391         union power_supply_propval *val)
392 {
393         int ret;
394
395         ret = bq20z75_read_word_data(client,
396                 bq20z75_data[REG_SERIAL_NUMBER].addr);
397         if (ret < 0)
398                 return ret;
399
400         ret = sprintf(bq20z75_serial, "%04x", ret);
401         val->strval = bq20z75_serial;
402
403         return 0;
404 }
405
406 static int bq20z75_get_property_index(struct i2c_client *client,
407         enum power_supply_property psp)
408 {
409         int count;
410         for (count = 0; count < ARRAY_SIZE(bq20z75_data); count++)
411                 if (psp == bq20z75_data[count].psp)
412                         return count;
413
414         dev_warn(&client->dev,
415                 "%s: Invalid Property - %d\n", __func__, psp);
416
417         return -EINVAL;
418 }
419
420 static int bq20z75_get_property(struct power_supply *psy,
421         enum power_supply_property psp,
422         union power_supply_propval *val)
423 {
424         int ret = 0;
425         struct bq20z75_info *bq20z75_device = container_of(psy,
426                                 struct bq20z75_info, power_supply);
427         struct i2c_client *client = bq20z75_device->client;
428
429         switch (psp) {
430         case POWER_SUPPLY_PROP_PRESENT:
431         case POWER_SUPPLY_PROP_HEALTH:
432                 ret = bq20z75_get_battery_presence_and_health(client, psp, val);
433                 break;
434
435         case POWER_SUPPLY_PROP_TECHNOLOGY:
436                 val->intval = POWER_SUPPLY_TECHNOLOGY_LION;
437                 break;
438
439         case POWER_SUPPLY_PROP_ENERGY_NOW:
440         case POWER_SUPPLY_PROP_ENERGY_FULL:
441         case POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN:
442         case POWER_SUPPLY_PROP_CHARGE_NOW:
443         case POWER_SUPPLY_PROP_CHARGE_FULL:
444         case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
445         case POWER_SUPPLY_PROP_CAPACITY:
446                 ret = bq20z75_get_property_index(client, psp);
447                 if (ret < 0)
448                         break;
449
450                 ret = bq20z75_get_battery_capacity(client, ret, psp, val);
451                 break;
452
453         case POWER_SUPPLY_PROP_SERIAL_NUMBER:
454                 ret = bq20z75_get_battery_serial_number(client, val);
455                 break;
456
457         case POWER_SUPPLY_PROP_STATUS:
458         case POWER_SUPPLY_PROP_CYCLE_COUNT:
459         case POWER_SUPPLY_PROP_VOLTAGE_NOW:
460         case POWER_SUPPLY_PROP_CURRENT_NOW:
461         case POWER_SUPPLY_PROP_TEMP:
462         case POWER_SUPPLY_PROP_TIME_TO_EMPTY_AVG:
463         case POWER_SUPPLY_PROP_TIME_TO_FULL_AVG:
464         case POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN:
465                 ret = bq20z75_get_property_index(client, psp);
466                 if (ret < 0)
467                         break;
468
469                 ret = bq20z75_get_battery_property(client, ret, psp, val);
470                 break;
471
472         default:
473                 dev_err(&client->dev,
474                         "%s: INVALID property\n", __func__);
475                 return -EINVAL;
476         }
477
478         if (!bq20z75_device->enable_detection)
479                 goto done;
480
481         if (!bq20z75_device->gpio_detect &&
482                 bq20z75_device->is_present != (ret >= 0)) {
483                 bq20z75_device->is_present = (ret >= 0);
484                 power_supply_changed(&bq20z75_device->power_supply);
485         }
486
487 done:
488         if (!ret) {
489                 /* Convert units to match requirements for power supply class */
490                 bq20z75_unit_adjustment(client, psp, val);
491         }
492
493         dev_dbg(&client->dev,
494                 "%s: property = %d, value = %d\n", __func__, psp, val->intval);
495
496         return ret;
497 }
498
499 static irqreturn_t bq20z75_irq(int irq, void *devid)
500 {
501         struct power_supply *battery = devid;
502
503         power_supply_changed(battery);
504
505         return IRQ_HANDLED;
506 }
507
508 static int __devinit bq20z75_probe(struct i2c_client *client,
509         const struct i2c_device_id *id)
510 {
511         struct bq20z75_info *bq20z75_device;
512         struct bq20z75_platform_data *pdata = client->dev.platform_data;
513         int rc;
514         int irq;
515
516         bq20z75_device = kzalloc(sizeof(struct bq20z75_info), GFP_KERNEL);
517         if (!bq20z75_device)
518                 return -ENOMEM;
519
520         bq20z75_device->client = client;
521         bq20z75_device->enable_detection = false;
522         bq20z75_device->gpio_detect = false;
523         bq20z75_device->power_supply.name = "battery";
524         bq20z75_device->power_supply.type = POWER_SUPPLY_TYPE_BATTERY;
525         bq20z75_device->power_supply.properties = bq20z75_properties;
526         bq20z75_device->power_supply.num_properties =
527                 ARRAY_SIZE(bq20z75_properties);
528         bq20z75_device->power_supply.get_property = bq20z75_get_property;
529
530         if (pdata) {
531                 bq20z75_device->gpio_detect =
532                         gpio_is_valid(pdata->battery_detect);
533                 bq20z75_device->pdata = pdata;
534         }
535
536         i2c_set_clientdata(client, bq20z75_device);
537
538         if (!bq20z75_device->gpio_detect)
539                 goto skip_gpio;
540
541         rc = gpio_request(pdata->battery_detect, dev_name(&client->dev));
542         if (rc) {
543                 dev_warn(&client->dev, "Failed to request gpio: %d\n", rc);
544                 bq20z75_device->gpio_detect = false;
545                 goto skip_gpio;
546         }
547
548         rc = gpio_direction_input(pdata->battery_detect);
549         if (rc) {
550                 dev_warn(&client->dev, "Failed to get gpio as input: %d\n", rc);
551                 gpio_free(pdata->battery_detect);
552                 bq20z75_device->gpio_detect = false;
553                 goto skip_gpio;
554         }
555
556         irq = gpio_to_irq(pdata->battery_detect);
557         if (irq <= 0) {
558                 dev_warn(&client->dev, "Failed to get gpio as irq: %d\n", irq);
559                 gpio_free(pdata->battery_detect);
560                 bq20z75_device->gpio_detect = false;
561                 goto skip_gpio;
562         }
563
564         rc = request_irq(irq, bq20z75_irq,
565                 IRQF_TRIGGER_RISING | IRQF_TRIGGER_FALLING,
566                 dev_name(&client->dev), &bq20z75_device->power_supply);
567         if (rc) {
568                 dev_warn(&client->dev, "Failed to request irq: %d\n", rc);
569                 gpio_free(pdata->battery_detect);
570                 bq20z75_device->gpio_detect = false;
571                 goto skip_gpio;
572         }
573
574         bq20z75_device->irq = irq;
575
576 skip_gpio:
577
578         rc = power_supply_register(&client->dev, &bq20z75_device->power_supply);
579         if (rc) {
580                 dev_err(&client->dev,
581                         "%s: Failed to register power supply\n", __func__);
582                 goto exit_psupply;
583         }
584
585         dev_info(&client->dev,
586                 "%s: battery gas gauge device registered\n", client->name);
587
588         return 0;
589
590 exit_psupply:
591         if (bq20z75_device->irq)
592                 free_irq(bq20z75_device->irq, &bq20z75_device->power_supply);
593         if (bq20z75_device->gpio_detect)
594                 gpio_free(pdata->battery_detect);
595
596         kfree(bq20z75_device);
597
598         return rc;
599 }
600
601 static int __devexit bq20z75_remove(struct i2c_client *client)
602 {
603         struct bq20z75_info *bq20z75_device = i2c_get_clientdata(client);
604
605         if (bq20z75_device->irq)
606                 free_irq(bq20z75_device->irq, &bq20z75_device->power_supply);
607         if (bq20z75_device->gpio_detect)
608                 gpio_free(bq20z75_device->pdata->battery_detect);
609
610         power_supply_unregister(&bq20z75_device->power_supply);
611         kfree(bq20z75_device);
612         bq20z75_device = NULL;
613
614         return 0;
615 }
616
617 #if defined CONFIG_PM
618 static int bq20z75_suspend(struct i2c_client *client,
619         pm_message_t state)
620 {
621         s32 ret;
622
623         /* write to manufacturer access with sleep command */
624         ret = bq20z75_write_word_data(client,
625                 bq20z75_data[REG_MANUFACTURER_DATA].addr,
626                 MANUFACTURER_ACCESS_SLEEP);
627         if (ret < 0)
628                 return ret;
629
630         return 0;
631 }
632 #else
633 #define bq20z75_suspend         NULL
634 #endif
635 /* any smbus transaction will wake up bq20z75 */
636 #define bq20z75_resume          NULL
637
638 static const struct i2c_device_id bq20z75_id[] = {
639         { "bq20z75", 0 },
640         {}
641 };
642
643 static struct i2c_driver bq20z75_battery_driver = {
644         .probe          = bq20z75_probe,
645         .remove         = __devexit_p(bq20z75_remove),
646         .suspend        = bq20z75_suspend,
647         .resume         = bq20z75_resume,
648         .id_table       = bq20z75_id,
649         .driver = {
650                 .name   = "bq20z75-battery",
651         },
652 };
653
654 static int __init bq20z75_battery_init(void)
655 {
656         return i2c_add_driver(&bq20z75_battery_driver);
657 }
658 module_init(bq20z75_battery_init);
659
660 static void __exit bq20z75_battery_exit(void)
661 {
662         i2c_del_driver(&bq20z75_battery_driver);
663 }
664 module_exit(bq20z75_battery_exit);
665