First cut at the Code Generator using the TableGen methodology.
[oota-llvm.git] / include / llvm / Target / TargetInstrInfo.h
1 //===-- llvm/Target/TargetInstrInfo.h - Instruction Info --------*- C++ -*-===//
2 //
3 // This file describes the target machine instructions to the code generator.
4 //
5 //===----------------------------------------------------------------------===//
6
7 #ifndef LLVM_TARGET_TARGETINSTRINFO_H
8 #define LLVM_TARGET_TARGETINSTRINFO_H
9
10 #include "Support/DataTypes.h"
11 #include <vector>
12
13 class MachineInstr;
14 class TargetMachine;
15 class Value;
16 class Instruction;
17 class Constant;
18 class Function;
19 class MachineCodeForInstruction;
20
21 //---------------------------------------------------------------------------
22 // Data types used to define information about a single machine instruction
23 //---------------------------------------------------------------------------
24
25 typedef int MachineOpCode;
26 typedef unsigned InstrSchedClass;
27
28 const MachineOpCode INVALID_MACHINE_OPCODE = -1;
29
30
31 //---------------------------------------------------------------------------
32 // struct TargetInstrDescriptor:
33 //      Predefined information about each machine instruction.
34 //      Designed to initialized statically.
35 //
36
37 const unsigned M_NOP_FLAG               = 1 << 0;
38 const unsigned M_BRANCH_FLAG            = 1 << 1;
39 const unsigned M_CALL_FLAG              = 1 << 2;
40 const unsigned M_RET_FLAG               = 1 << 3;
41 const unsigned M_ARITH_FLAG             = 1 << 4;
42 const unsigned M_CC_FLAG                = 1 << 6;
43 const unsigned M_LOGICAL_FLAG           = 1 << 6;
44 const unsigned M_INT_FLAG               = 1 << 7;
45 const unsigned M_FLOAT_FLAG             = 1 << 8;
46 const unsigned M_CONDL_FLAG             = 1 << 9;
47 const unsigned M_LOAD_FLAG              = 1 << 10;
48 const unsigned M_PREFETCH_FLAG          = 1 << 11;
49 const unsigned M_STORE_FLAG             = 1 << 12;
50 const unsigned M_DUMMY_PHI_FLAG = 1 << 13;
51 const unsigned M_PSEUDO_FLAG           = 1 << 14;       // Pseudo instruction
52 // 3-addr instructions which really work like 2-addr ones, eg. X86 add/sub
53 const unsigned M_2_ADDR_FLAG           = 1 << 15;
54
55 // M_TERMINATOR_FLAG - Is this instruction part of the terminator for a basic
56 // block?  Typically this is things like return and branch instructions.
57 // Various passes use this to insert code into the bottom of a basic block, but
58 // before control flow occurs.
59 const unsigned M_TERMINATOR_FLAG       = 1 << 16;
60
61 struct TargetInstrDescriptor {
62   const char *    Name;          // Assembly language mnemonic for the opcode.
63   int             numOperands;   // Number of args; -1 if variable #args
64   int             resultPos;     // Position of the result; -1 if no result
65   unsigned        maxImmedConst; // Largest +ve constant in IMMMED field or 0.
66   bool            immedIsSignExtended; // Is IMMED field sign-extended? If so,
67                                  //   smallest -ve value is -(maxImmedConst+1).
68   unsigned        numDelaySlots; // Number of delay slots after instruction
69   unsigned        latency;       // Latency in machine cycles
70   InstrSchedClass schedClass;    // enum  identifying instr sched class
71   unsigned        Flags;         // flags identifying machine instr class
72   unsigned        TSFlags;       // Target Specific Flag values
73   const unsigned *ImplicitUses;  // Registers implicitly read by this instr
74   const unsigned *ImplicitDefs;  // Registers implicitly defined by this instr
75 };
76
77
78 //---------------------------------------------------------------------------
79 /// 
80 /// TargetInstrInfo - Interface to description of machine instructions
81 /// 
82 class TargetInstrInfo {
83   const TargetInstrDescriptor* desc;    // raw array to allow static init'n
84   unsigned descSize;                    // number of entries in the desc array
85   unsigned numRealOpCodes;              // number of non-dummy op codes
86   
87   TargetInstrInfo(const TargetInstrInfo &);  // DO NOT IMPLEMENT
88   void operator=(const TargetInstrInfo &);   // DO NOT IMPLEMENT
89 public:
90   TargetInstrInfo(const TargetInstrDescriptor *desc, unsigned descSize,
91                   unsigned numRealOpCodes);
92   virtual ~TargetInstrInfo();
93
94   // Invariant: All instruction sets use opcode #0 as the PHI instruction and
95   // opcode #1 as the noop instruction.
96   enum {
97     PHI = 0, NOOP = 1
98   };
99   
100   unsigned getNumRealOpCodes()  const { return numRealOpCodes; }
101   unsigned getNumTotalOpCodes() const { return descSize; }
102   
103   /// get - Return the machine instruction descriptor that corresponds to the
104   /// specified instruction opcode.
105   ///
106   const TargetInstrDescriptor& get(MachineOpCode opCode) const {
107     assert(opCode >= 0 && opCode < (int)descSize);
108     return desc[opCode];
109   }
110
111   /// print - Print out the specified machine instruction in the appropriate
112   /// target specific assembly language.  If this method is not overridden, the
113   /// default implementation uses the crummy machine independant printer.
114   ///
115   virtual void print(const MachineInstr *MI, std::ostream &O,
116                      const TargetMachine &TM) const;
117
118   const char *getName(MachineOpCode opCode) const {
119     return get(opCode).Name;
120   }
121   
122   int getNumOperands(MachineOpCode opCode) const {
123     return get(opCode).numOperands;
124   }
125   
126   int getResultPos(MachineOpCode opCode) const {
127     return get(opCode).resultPos;
128   }
129   
130   unsigned getNumDelaySlots(MachineOpCode opCode) const {
131     return get(opCode).numDelaySlots;
132   }
133   
134   InstrSchedClass getSchedClass(MachineOpCode opCode) const {
135     return get(opCode).schedClass;
136   }
137   
138   //
139   // Query instruction class flags according to the machine-independent
140   // flags listed above.
141   // 
142   bool isNop(MachineOpCode opCode) const {
143     return get(opCode).Flags & M_NOP_FLAG;
144   }
145   bool isBranch(MachineOpCode opCode) const {
146     return get(opCode).Flags & M_BRANCH_FLAG;
147   }
148   bool isCall(MachineOpCode opCode) const {
149     return get(opCode).Flags & M_CALL_FLAG;
150   }
151   bool isReturn(MachineOpCode opCode) const {
152     return get(opCode).Flags & M_RET_FLAG;
153   }
154   bool isControlFlow(MachineOpCode opCode) const {
155     return get(opCode).Flags & M_BRANCH_FLAG
156         || get(opCode).Flags & M_CALL_FLAG
157         || get(opCode).Flags & M_RET_FLAG;
158   }
159   bool isArith(MachineOpCode opCode) const {
160     return get(opCode).Flags & M_ARITH_FLAG;
161   }
162   bool isCCInstr(MachineOpCode opCode) const {
163     return get(opCode).Flags & M_CC_FLAG;
164   }
165   bool isLogical(MachineOpCode opCode) const {
166     return get(opCode).Flags & M_LOGICAL_FLAG;
167   }
168   bool isIntInstr(MachineOpCode opCode) const {
169     return get(opCode).Flags & M_INT_FLAG;
170   }
171   bool isFloatInstr(MachineOpCode opCode) const {
172     return get(opCode).Flags & M_FLOAT_FLAG;
173   }
174   bool isConditional(MachineOpCode opCode) const { 
175     return get(opCode).Flags & M_CONDL_FLAG;
176   }
177   bool isLoad(MachineOpCode opCode) const {
178     return get(opCode).Flags & M_LOAD_FLAG;
179   }
180   bool isPrefetch(MachineOpCode opCode) const {
181     return get(opCode).Flags & M_PREFETCH_FLAG;
182   }
183   bool isLoadOrPrefetch(MachineOpCode opCode) const {
184     return get(opCode).Flags & M_LOAD_FLAG
185         || get(opCode).Flags & M_PREFETCH_FLAG;
186   }
187   bool isStore(MachineOpCode opCode) const {
188     return get(opCode).Flags & M_STORE_FLAG;
189   }
190   bool isMemoryAccess(MachineOpCode opCode) const {
191     return get(opCode).Flags & M_LOAD_FLAG
192         || get(opCode).Flags & M_PREFETCH_FLAG
193         || get(opCode).Flags & M_STORE_FLAG;
194   }
195   bool isDummyPhiInstr(MachineOpCode opCode) const {
196     return get(opCode).Flags & M_DUMMY_PHI_FLAG;
197   }
198   bool isPseudoInstr(MachineOpCode opCode) const {
199     return get(opCode).Flags & M_PSEUDO_FLAG;
200   }
201   bool isTwoAddrInstr(MachineOpCode opCode) const {
202     return get(opCode).Flags & M_2_ADDR_FLAG;
203   }
204   bool isTerminatorInstr(unsigned Opcode) const {
205     return get(Opcode).Flags & M_TERMINATOR_FLAG;
206   }
207
208   // Check if an instruction can be issued before its operands are ready,
209   // or if a subsequent instruction that uses its result can be issued
210   // before the results are ready.
211   // Default to true since most instructions on many architectures allow this.
212   // 
213   virtual bool hasOperandInterlock(MachineOpCode opCode) const {
214     return true;
215   }
216   
217   virtual bool hasResultInterlock(MachineOpCode opCode) const {
218     return true;
219   }
220   
221   // 
222   // Latencies for individual instructions and instruction pairs
223   // 
224   virtual int minLatency(MachineOpCode opCode) const {
225     return get(opCode).latency;
226   }
227   
228   virtual int maxLatency(MachineOpCode opCode) const {
229     return get(opCode).latency;
230   }
231
232   //
233   // Which operand holds an immediate constant?  Returns -1 if none
234   // 
235   virtual int getImmedConstantPos(MachineOpCode opCode) const {
236     return -1; // immediate position is machine specific, so say -1 == "none"
237   }
238   
239   // Check if the specified constant fits in the immediate field
240   // of this machine instruction
241   // 
242   virtual bool constantFitsInImmedField(MachineOpCode opCode,
243                                         int64_t intValue) const;
244   
245   // Return the largest +ve constant that can be held in the IMMMED field
246   // of this machine instruction.
247   // isSignExtended is set to true if the value is sign-extended before use
248   // (this is true for all immediate fields in SPARC instructions).
249   // Return 0 if the instruction has no IMMED field.
250   // 
251   virtual uint64_t maxImmedConstant(MachineOpCode opCode,
252                                     bool &isSignExtended) const {
253     isSignExtended = get(opCode).immedIsSignExtended;
254     return get(opCode).maxImmedConst;
255   }
256
257   //-------------------------------------------------------------------------
258   // Queries about representation of LLVM quantities (e.g., constants)
259   //-------------------------------------------------------------------------
260
261   /// ConstantTypeMustBeLoaded - Test if this type of constant must be loaded
262   /// from memory into a register, i.e., cannot be set bitwise in register and
263   /// cannot use immediate fields of instructions.  Note that this only makes
264   /// sense for primitive types.
265   ///
266   virtual bool ConstantTypeMustBeLoaded(const Constant* CV) const;
267
268   // Test if this constant may not fit in the immediate field of the
269   // machine instructions (probably) generated for this instruction.
270   // 
271   virtual bool ConstantMayNotFitInImmedField(const Constant* CV,
272                                              const Instruction* I) const {
273     return true;                        // safe but very conservative
274   }
275
276
277   /// createNOPinstr - returns the target's implementation of NOP, which is
278   /// usually a pseudo-instruction, implemented by a degenerate version of
279   /// another instruction, e.g. X86: xchg ax, ax; SparcV9: sethi g0, 0
280   ///
281   virtual MachineInstr* createNOPinstr() const = 0;
282
283   /// isNOPinstr - since we no longer have a special NOP opcode, we need to know
284   /// if a given instruction is interpreted as an `official' NOP instr, i.e.,
285   /// there may be more than one way to `do nothing' but only one canonical
286   /// way to slack off.
287   ///
288   virtual bool isNOPinstr(const MachineInstr &MI) const = 0;
289
290   //-------------------------------------------------------------------------
291   // Code generation support for creating individual machine instructions
292   //
293   // WARNING: These methods are Sparc specific
294   //
295   //-------------------------------------------------------------------------
296
297   // Get certain common op codes for the current target.  this and all the
298   // Create* methods below should be moved to a machine code generation class
299   // 
300   virtual MachineOpCode getNOPOpCode() const { abort(); }
301
302   // Create an instruction sequence to put the constant `val' into
303   // the virtual register `dest'.  `val' may be a Constant or a
304   // GlobalValue, viz., the constant address of a global variable or function.
305   // The generated instructions are returned in `mvec'.
306   // Any temp. registers (TmpInstruction) created are recorded in mcfi.
307   // Symbolic constants or constants that must be accessed from memory
308   // are added to the constant pool via MachineFunction::get(F).
309   // 
310   virtual void  CreateCodeToLoadConst(const TargetMachine& target,
311                                       Function* F,
312                                       Value* val,
313                                       Instruction* dest,
314                                       std::vector<MachineInstr*>& mvec,
315                                       MachineCodeForInstruction& mcfi) const {
316     abort();
317   }
318   
319   // Create an instruction sequence to copy an integer value `val'
320   // to a floating point value `dest' by copying to memory and back.
321   // val must be an integral type.  dest must be a Float or Double.
322   // The generated instructions are returned in `mvec'.
323   // Any temp. registers (TmpInstruction) created are recorded in mcfi.
324   // Any stack space required is allocated via mcff.
325   // 
326   virtual void CreateCodeToCopyIntToFloat(const TargetMachine& target,
327                                           Function* F,
328                                           Value* val,
329                                           Instruction* dest,
330                                           std::vector<MachineInstr*>& mvec,
331                                           MachineCodeForInstruction& MI) const {
332     abort();
333   }
334
335   // Similarly, create an instruction sequence to copy an FP value
336   // `val' to an integer value `dest' by copying to memory and back.
337   // The generated instructions are returned in `mvec'.
338   // Any temp. registers (TmpInstruction) created are recorded in mcfi.
339   // Any stack space required is allocated via mcff.
340   // 
341   virtual void CreateCodeToCopyFloatToInt(const TargetMachine& target,
342                                           Function* F,
343                                           Value* val,
344                                           Instruction* dest,
345                                           std::vector<MachineInstr*>& mvec,
346                                           MachineCodeForInstruction& MI) const {
347     abort();
348   }
349   
350   // Create instruction(s) to copy src to dest, for arbitrary types
351   // The generated instructions are returned in `mvec'.
352   // Any temp. registers (TmpInstruction) created are recorded in mcfi.
353   // Any stack space required is allocated via mcff.
354   // 
355   virtual void CreateCopyInstructionsByType(const TargetMachine& target,
356                                             Function* F,
357                                             Value* src,
358                                             Instruction* dest,
359                                             std::vector<MachineInstr*>& mvec,
360                                           MachineCodeForInstruction& MI) const {
361     abort();
362   }
363
364   // Create instruction sequence to produce a sign-extended register value
365   // from an arbitrary sized value (sized in bits, not bytes).
366   // The generated instructions are appended to `mvec'.
367   // Any temp. registers (TmpInstruction) created are recorded in mcfi.
368   // Any stack space required is allocated via mcff.
369   // 
370   virtual void CreateSignExtensionInstructions(const TargetMachine& target,
371                                        Function* F,
372                                        Value* srcVal,
373                                        Value* destVal,
374                                        unsigned numLowBits,
375                                        std::vector<MachineInstr*>& mvec,
376                                        MachineCodeForInstruction& MI) const {
377     abort();
378   }
379
380   // Create instruction sequence to produce a zero-extended register value
381   // from an arbitrary sized value (sized in bits, not bytes).
382   // The generated instructions are appended to `mvec'.
383   // Any temp. registers (TmpInstruction) created are recorded in mcfi.
384   // Any stack space required is allocated via mcff.
385   // 
386   virtual void CreateZeroExtensionInstructions(const TargetMachine& target,
387                                        Function* F,
388                                        Value* srcVal,
389                                        Value* destVal,
390                                        unsigned srcSizeInBits,
391                                        std::vector<MachineInstr*>& mvec,
392                                        MachineCodeForInstruction& mcfi) const {
393     abort();
394   }
395 };
396
397 #endif