-zero'; this is important for negative voltage measurements. All voltage
-inputs can measure voltages between 0 and 4.08 volts, with a resolution of
-0.016 volt (except IT8603E, IT8721F/IT8758E and IT8728F: 0.012 volt.) The
-battery voltage in8 does not have limit registers.
-
-On the IT8603E, IT8721F/IT8758E, IT8781F, IT8782F, and IT8783E/F, some
+zero'; this is important for negative voltage measurements. On most chips, all
+voltage inputs can measure voltages between 0 and 4.08 volts, with a resolution
+of 0.016 volt. IT8603E, IT8721F/IT8758E and IT8728F can measure between 0 and
+3.06 volts, with a resolution of 0.012 volt. IT8732F can measure between 0 and
+2.8 volts with a resolution of 0.0109 volt. The battery voltage in8 does not
+have limit registers.
+
+On the IT8603E, IT8721F/IT8758E, IT8732F, IT8781F, IT8782F, and IT8783E/F, some