net: mvneta: do not schedule in mvneta_tx_timeout
[firefly-linux-kernel-4.4.55.git] / drivers / thermal / cpu_cooling.c
index 8dc44cbb3e09fe253546347e376c0834957efc1e..c94bf2e5de629419c8e00e29f2cf23ac4507c365 100644 (file)
  *
  * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  */
-#include <linux/kernel.h>
 #include <linux/module.h>
 #include <linux/thermal.h>
-#include <linux/platform_device.h>
 #include <linux/cpufreq.h>
 #include <linux/err.h>
 #include <linux/slab.h>
 #include <linux/cpu_cooling.h>
 
 /**
- * struct cpufreq_cooling_device
+ * struct cpufreq_cooling_device - data for cooling device with cpufreq
  * @id: unique integer value corresponding to each cpufreq_cooling_device
  *     registered.
- * @cool_dev: thermal_cooling_device pointer to keep track of the the
- *     egistered cooling device.
+ * @cool_dev: thermal_cooling_device pointer to keep track of the
+ *     registered cooling device.
  * @cpufreq_state: integer value representing the current state of cpufreq
  *     cooling devices.
  * @cpufreq_val: integer value representing the absolute value of the clipped
  *     frequency.
  * @allowed_cpus: all the cpus involved for this cpufreq_cooling_device.
- * @node: list_head to link all cpufreq_cooling_device together.
  *
  * This structure is required for keeping information of each
- * cpufreq_cooling_device registered as a list whose head is represented by
- * cooling_cpufreq_list. In order to prevent corruption of this list a
+ * cpufreq_cooling_device registered. In order to prevent corruption of this a
  * mutex lock cooling_cpufreq_lock is used.
  */
 struct cpufreq_cooling_device {
@@ -54,9 +50,7 @@ struct cpufreq_cooling_device {
        unsigned int cpufreq_state;
        unsigned int cpufreq_val;
        struct cpumask allowed_cpus;
-       struct list_head node;
 };
-static LIST_HEAD(cooling_cpufreq_list);
 static DEFINE_IDR(cpufreq_idr);
 static DEFINE_MUTEX(cooling_cpufreq_lock);
 
@@ -70,6 +64,11 @@ static struct cpufreq_cooling_device *notify_device;
  * get_idr - function to get a unique id.
  * @idr: struct idr * handle used to create a id.
  * @id: int * value generated by this function.
+ *
+ * This function will populate @id with an unique
+ * id, using the idr API.
+ *
+ * Return: 0 on success, an error code on failure.
  */
 static int get_idr(struct idr *idr, int *id)
 {
@@ -81,6 +80,7 @@ static int get_idr(struct idr *idr, int *id)
        if (unlikely(ret < 0))
                return ret;
        *id = ret;
+
        return 0;
 }
 
@@ -99,63 +99,162 @@ static void release_idr(struct idr *idr, int id)
 /* Below code defines functions to be used for cpufreq as cooling device */
 
 /**
- * is_cpufreq_valid - function to check if a cpu has frequency transition policy.
+ * is_cpufreq_valid - function to check frequency transitioning capability.
  * @cpu: cpu for which check is needed.
+ *
+ * This function will check the current state of the system if
+ * it is capable of changing the frequency for a given @cpu.
+ *
+ * Return: 0 if the system is not currently capable of changing
+ * the frequency of given cpu. !0 in case the frequency is changeable.
  */
 static int is_cpufreq_valid(int cpu)
 {
        struct cpufreq_policy policy;
+
        return !cpufreq_get_policy(&policy, cpu);
 }
 
+enum cpufreq_cooling_property {
+       GET_LEVEL,
+       GET_FREQ,
+       GET_MAXL,
+};
+
 /**
- * get_cpu_frequency - get the absolute value of frequency from level.
- * @cpu: cpu for which frequency is fetched.
- * @level: level of frequency, equals cooling state of cpu cooling device
- *     e.g level=0 --> 1st MAX FREQ, level=1 ---> 2nd MAX FREQ, .... etc
+ * get_property - fetch a property of interest for a give cpu.
+ * @cpu: cpu for which the property is required
+ * @input: query parameter
+ * @output: query return
+ * @property: type of query (frequency, level, max level)
+ *
+ * This is the common function to
+ * 1. get maximum cpu cooling states
+ * 2. translate frequency to cooling state
+ * 3. translate cooling state to frequency
+ * Note that the code may be not in good shape
+ * but it is written in this way in order to:
+ * a) reduce duplicate code as most of the code can be shared.
+ * b) make sure the logic is consistent when translating between
+ *    cooling states and frequencies.
+ *
+ * Return: 0 on success, -EINVAL when invalid parameters are passed.
  */
-static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level)
+static int get_property(unsigned int cpu, unsigned long input,
+                       unsigned int *output,
+                       enum cpufreq_cooling_property property)
 {
-       int ret = 0, i = 0;
-       unsigned long level_index;
-       bool descend = false;
+       int i, j;
+       unsigned long max_level = 0, level = 0;
+       unsigned int freq = CPUFREQ_ENTRY_INVALID;
+       int descend = -1;
        struct cpufreq_frequency_table *table =
                                        cpufreq_frequency_get_table(cpu);
+
+       if (!output)
+               return -EINVAL;
+
        if (!table)
-               return ret;
+               return -EINVAL;
 
-       while (table[i].frequency != CPUFREQ_TABLE_END) {
+       for (i = 0; table[i].frequency != CPUFREQ_TABLE_END; i++) {
+               /* ignore invalid entries */
                if (table[i].frequency == CPUFREQ_ENTRY_INVALID)
                        continue;
 
-               /*check if table in ascending or descending order*/
-               if ((table[i + 1].frequency != CPUFREQ_TABLE_END) &&
-                       (table[i + 1].frequency < table[i].frequency)
-                       && !descend) {
-                       descend = true;
-               }
+               /* ignore duplicate entry */
+               if (freq == table[i].frequency)
+                       continue;
+
+               /* get the frequency order */
+               if (freq != CPUFREQ_ENTRY_INVALID && descend != -1)
+                       descend = !!(freq > table[i].frequency);
 
-               /*return if level matched and table in descending order*/
-               if (descend && i == level)
-                       return table[i].frequency;
-               i++;
+               freq = table[i].frequency;
+               max_level++;
        }
-       i--;
 
-       if (level > i || descend)
-               return ret;
-       level_index = i - level;
+       /* get max level */
+       if (property == GET_MAXL) {
+               *output = (unsigned int)max_level;
+               return 0;
+       }
 
-       /*Scan the table in reverse order and match the level*/
-       while (i >= 0) {
+       if (property == GET_FREQ)
+               level = descend ? input : (max_level - input - 1);
+
+       for (i = 0, j = 0; table[i].frequency != CPUFREQ_TABLE_END; i++) {
+               /* ignore invalid entry */
                if (table[i].frequency == CPUFREQ_ENTRY_INVALID)
                        continue;
-               /*return if level matched*/
-               if (i == level_index)
-                       return table[i].frequency;
-               i--;
+
+               /* ignore duplicate entry */
+               if (freq == table[i].frequency)
+                       continue;
+
+               /* now we have a valid frequency entry */
+               freq = table[i].frequency;
+
+               if (property == GET_LEVEL && (unsigned int)input == freq) {
+                       /* get level by frequency */
+                       *output = descend ? j : (max_level - j - 1);
+                       return 0;
+               }
+               if (property == GET_FREQ && level == j) {
+                       /* get frequency by level */
+                       *output = freq;
+                       return 0;
+               }
+               j++;
        }
-       return ret;
+
+       return -EINVAL;
+}
+
+/**
+ * cpufreq_cooling_get_level - for a give cpu, return the cooling level.
+ * @cpu: cpu for which the level is required
+ * @freq: the frequency of interest
+ *
+ * This function will match the cooling level corresponding to the
+ * requested @freq and return it.
+ *
+ * Return: The matched cooling level on success or THERMAL_CSTATE_INVALID
+ * otherwise.
+ */
+unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
+{
+       unsigned int val;
+
+       if (get_property(cpu, (unsigned long)freq, &val, GET_LEVEL))
+               return THERMAL_CSTATE_INVALID;
+
+       return (unsigned long)val;
+}
+EXPORT_SYMBOL_GPL(cpufreq_cooling_get_level);
+
+/**
+ * get_cpu_frequency - get the absolute value of frequency from level.
+ * @cpu: cpu for which frequency is fetched.
+ * @level: cooling level
+ *
+ * This function matches cooling level with frequency. Based on a cooling level
+ * of frequency, equals cooling state of cpu cooling device, it will return
+ * the corresponding frequency.
+ *     e.g level=0 --> 1st MAX FREQ, level=1 ---> 2nd MAX FREQ, .... etc
+ *
+ * Return: 0 on error, the corresponding frequency otherwise.
+ */
+static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level)
+{
+       int ret = 0;
+       unsigned int freq;
+
+       ret = get_property(cpu, level, &freq, GET_FREQ);
+       if (ret)
+               return 0;
+
+       return freq;
 }
 
 /**
@@ -163,13 +262,19 @@ static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level)
  * @cpufreq_device: cpufreq_cooling_device pointer containing frequency
  *     clipping data.
  * @cooling_state: value of the cooling state.
+ *
+ * Function used to make sure the cpufreq layer is aware of current thermal
+ * limits. The limits are applied by updating the cpufreq policy.
+ *
+ * Return: 0 on success, an error code otherwise (-EINVAL in case wrong
+ * cooling state).
  */
 static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device,
-                               unsigned long cooling_state)
+                                unsigned long cooling_state)
 {
        unsigned int cpuid, clip_freq;
-       struct cpumask *maskPtr = &cpufreq_device->allowed_cpus;
-       unsigned int cpu = cpumask_any(maskPtr);
+       struct cpumask *mask = &cpufreq_device->allowed_cpus;
+       unsigned int cpu = cpumask_any(mask);
 
 
        /* Check if the old cooling action is same as new cooling action */
@@ -184,7 +289,7 @@ static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device,
        cpufreq_device->cpufreq_val = clip_freq;
        notify_device = cpufreq_device;
 
-       for_each_cpu(cpuid, maskPtr) {
+       for_each_cpu(cpuid, mask) {
                if (is_cpufreq_valid(cpuid))
                        cpufreq_update_policy(cpuid);
        }
@@ -199,9 +304,15 @@ static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device,
  * @nb:        struct notifier_block * with callback info.
  * @event: value showing cpufreq event for which this function invoked.
  * @data: callback-specific data
+ *
+ * Callback to highjack the notification on cpufreq policy transition.
+ * Every time there is a change in policy, we will intercept and
+ * update the cpufreq policy with thermal constraints.
+ *
+ * Return: 0 (success)
  */
 static int cpufreq_thermal_notifier(struct notifier_block *nb,
-                                       unsigned long event, void *data)
+                                   unsigned long event, void *data)
 {
        struct cpufreq_policy *policy = data;
        unsigned long max_freq = 0;
@@ -212,7 +323,7 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
        if (cpumask_test_cpu(policy->cpu, &notify_device->allowed_cpus))
                max_freq = notify_device->cpufreq_val;
 
-       /* Never exceed user_policy.max*/
+       /* Never exceed user_policy.max */
        if (max_freq > policy->user_policy.max)
                max_freq = policy->user_policy.max;
 
@@ -222,50 +333,46 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
        return 0;
 }
 
-/*
- * cpufreq cooling device callback functions are defined below
- */
+/* cpufreq cooling device callback functions are defined below */
 
 /**
  * cpufreq_get_max_state - callback function to get the max cooling state.
  * @cdev: thermal cooling device pointer.
  * @state: fill this variable with the max cooling state.
+ *
+ * Callback for the thermal cooling device to return the cpufreq
+ * max cooling state.
+ *
+ * Return: 0 on success, an error code otherwise.
  */
 static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
                                 unsigned long *state)
 {
        struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
-       struct cpumask *maskPtr = &cpufreq_device->allowed_cpus;
+       struct cpumask *mask = &cpufreq_device->allowed_cpus;
        unsigned int cpu;
-       struct cpufreq_frequency_table *table;
-       unsigned long count = 0;
-       int i = 0;
-
-       cpu = cpumask_any(maskPtr);
-       table = cpufreq_frequency_get_table(cpu);
-       if (!table) {
-               *state = 0;
-               return 0;
-       }
+       unsigned int count = 0;
+       int ret;
 
-       for (i = 0; (table[i].frequency != CPUFREQ_TABLE_END); i++) {
-               if (table[i].frequency == CPUFREQ_ENTRY_INVALID)
-                       continue;
-               count++;
-       }
+       cpu = cpumask_any(mask);
 
-       if (count > 0) {
-               *state = --count;
-               return 0;
-       }
+       ret = get_property(cpu, 0, &count, GET_MAXL);
 
-       return -EINVAL;
+       if (count > 0)
+               *state = count;
+
+       return ret;
 }
 
 /**
  * cpufreq_get_cur_state - callback function to get the current cooling state.
  * @cdev: thermal cooling device pointer.
  * @state: fill this variable with the current cooling state.
+ *
+ * Callback for the thermal cooling device to return the cpufreq
+ * current cooling state.
+ *
+ * Return: 0 on success, an error code otherwise.
  */
 static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
                                 unsigned long *state)
@@ -273,6 +380,7 @@ static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
        struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
 
        *state = cpufreq_device->cpufreq_state;
+
        return 0;
 }
 
@@ -280,6 +388,11 @@ static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
  * cpufreq_set_cur_state - callback function to set the current cooling state.
  * @cdev: thermal cooling device pointer.
  * @state: set this variable to the current cooling state.
+ *
+ * Callback for the thermal cooling device to change the cpufreq
+ * current cooling state.
+ *
+ * Return: 0 on success, an error code otherwise.
  */
 static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
                                 unsigned long state)
@@ -304,9 +417,16 @@ static struct notifier_block thermal_cpufreq_notifier_block = {
 /**
  * cpufreq_cooling_register - function to create cpufreq cooling device.
  * @clip_cpus: cpumask of cpus where the frequency constraints will happen.
+ *
+ * This interface function registers the cpufreq cooling device with the name
+ * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
+ * cooling devices.
+ *
+ * Return: a valid struct thermal_cooling_device pointer on success,
+ * on failure, it returns a corresponding ERR_PTR().
  */
-struct thermal_cooling_device *cpufreq_cooling_register(
-       const struct cpumask *clip_cpus)
+struct thermal_cooling_device *
+cpufreq_cooling_register(const struct cpumask *clip_cpus)
 {
        struct thermal_cooling_device *cool_dev;
        struct cpufreq_cooling_device *cpufreq_dev = NULL;
@@ -315,9 +435,9 @@ struct thermal_cooling_device *cpufreq_cooling_register(
        int ret = 0, i;
        struct cpufreq_policy policy;
 
-       /*Verify that all the clip cpus have same freq_min, freq_max limit*/
+       /* Verify that all the clip cpus have same freq_min, freq_max limit */
        for_each_cpu(i, clip_cpus) {
-               /*continue if cpufreq policy not found and not return error*/
+               /* continue if cpufreq policy not found and not return error */
                if (!cpufreq_get_policy(&policy, i))
                        continue;
                if (min == 0 && max == 0) {
@@ -325,12 +445,12 @@ struct thermal_cooling_device *cpufreq_cooling_register(
                        max = policy.cpuinfo.max_freq;
                } else {
                        if (min != policy.cpuinfo.min_freq ||
-                               max != policy.cpuinfo.max_freq)
+                           max != policy.cpuinfo.max_freq)
                                return ERR_PTR(-EINVAL);
                }
        }
        cpufreq_dev = kzalloc(sizeof(struct cpufreq_cooling_device),
-                       GFP_KERNEL);
+                             GFP_KERNEL);
        if (!cpufreq_dev)
                return ERR_PTR(-ENOMEM);
 
@@ -342,10 +462,11 @@ struct thermal_cooling_device *cpufreq_cooling_register(
                return ERR_PTR(-EINVAL);
        }
 
-       sprintf(dev_name, "thermal-cpufreq-%d", cpufreq_dev->id);
+       snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
+                cpufreq_dev->id);
 
        cool_dev = thermal_cooling_device_register(dev_name, cpufreq_dev,
-                                               &cpufreq_cooling_ops);
+                                                  &cpufreq_cooling_ops);
        if (!cool_dev) {
                release_idr(&cpufreq_idr, cpufreq_dev->id);
                kfree(cpufreq_dev);
@@ -358,17 +479,20 @@ struct thermal_cooling_device *cpufreq_cooling_register(
        /* Register the notifier for first cpufreq cooling device */
        if (cpufreq_dev_count == 0)
                cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
-                                               CPUFREQ_POLICY_NOTIFIER);
+                                         CPUFREQ_POLICY_NOTIFIER);
        cpufreq_dev_count++;
 
        mutex_unlock(&cooling_cpufreq_lock);
+
        return cool_dev;
 }
-EXPORT_SYMBOL(cpufreq_cooling_register);
+EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
 
 /**
  * cpufreq_cooling_unregister - function to remove cpufreq cooling device.
  * @cdev: thermal cooling device pointer.
+ *
+ * This interface function unregisters the "thermal-cpufreq-%x" cooling device.
  */
 void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
 {
@@ -378,14 +502,13 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
        cpufreq_dev_count--;
 
        /* Unregister the notifier for the last cpufreq cooling device */
-       if (cpufreq_dev_count == 0) {
+       if (cpufreq_dev_count == 0)
                cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
-                                       CPUFREQ_POLICY_NOTIFIER);
-       }
+                                           CPUFREQ_POLICY_NOTIFIER);
        mutex_unlock(&cooling_cpufreq_lock);
 
        thermal_cooling_device_unregister(cpufreq_dev->cool_dev);
        release_idr(&cpufreq_idr, cpufreq_dev->id);
        kfree(cpufreq_dev);
 }
-EXPORT_SYMBOL(cpufreq_cooling_unregister);
+EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);