regulator: Refactor to use one da9052_ldo_ops/da9052_dcdc_ops for all LDOs/DCDCs
authorAxel Lin <axel.lin@gmail.com>
Thu, 15 Mar 2012 12:00:07 +0000 (20:00 +0800)
committerMark Brown <broonie@opensource.wolfsonmicro.com>
Sun, 1 Apr 2012 10:59:35 +0000 (11:59 +0100)
commit0ec446ea9a1cc86bfeb0c724a490701271d02fa5
tree47d64671ae6c217e460fb8fc0f0ef5b07f24c488
parent9210f05b4eb0e9d08b527417fa6ebc043a232bd6
regulator: Refactor to use one da9052_ldo_ops/da9052_dcdc_ops for all LDOs/DCDCs

In current implementation, da9052_ldo_ops and da9052_ldo5_6_ops are very
similar, only the set_voltage is slightly different.
da9052_buckperi_ops and da9052_dcdc_ops are also similar.

This patch adds da9052_regulator_set_voltage for the set_voltage callback
used by all LDOs and DCDCs. Rework da9052_get_regulator_voltage_sel and
da9052_set_dcdc_voltage to make it possible to be shared by all DCDCs.
Rework da9052_list_voltage to make it to be shared by all DCDCs and LDOs.

Then we can remove da9052_ldo5_6_ops and da9052_buckperi_ops.
We can also remove DA9052_LDO5_6 and DA9052_BUCKPERI macros which is not used
now.

Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
drivers/regulator/da9052-regulator.c