power: ds2781: Add voltage check before 100% reset
authorGreg Meiste <w30289@motorola.com>
Mon, 25 Apr 2011 23:06:50 +0000 (18:06 -0500)
committerRebecca Schultz Zavin <rebecca@android.com>
Wed, 27 Apr 2011 23:41:45 +0000 (16:41 -0700)
commit36b2966bdb62410a05215e6e3edcabfad801fa00
tree8e7bf7890a6747db35fa7e869ff77524919ff242
parent9c770a564a7a23f31138947097b709dd72fe2d80
power: ds2781: Add voltage check before 100% reset

Sanity check the voltage before performing the 100% coulumb
counter reset. This will prevent an inadvertent reset in case
charge complete is reported incorrectly by the system.

Change-Id: Iadcfbd13dee8bd1ce0bdc4186f1490c90d75251a
Signed-off-by: Greg Meiste <w30289@motorola.com>
drivers/power/ds2781_battery.c