iio: gyro: bmg160: fix endianness when reading axes
commit
95e7ff034175db7d8aefabe7716c4d42bea24fde upstream.
For big endian platforms, reading the axes will return
invalid values.
The device stores each axis value in a 16 bit little
endian register. The driver uses regmap_read_bulk to get
the axis value, resulting in a 16 bit little endian value.
This needs to be converted to cpu endianness to work
on big endian platforms.
Fix endianness for big endian platforms by converting
the values for the axes read from little endian to
cpu.
This is also partially fixed in commit
82d8e5da1a33 ("iio:
accel: bmg160: optimize transfers in trigger handler").
Signed-off-by: Irina Tirdea <irina.tirdea@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>