UPSTREAM: regulator: pwm: Retrieve correct voltage
The continuous PWM voltage regulator is caching the voltage value in
the ->volt_uV field. While most of the time this value should reflect the
real voltage, sometime it can be sightly different if the PWM device
rounded the set_duty_cycle request.
Moreover, this value is not valid until someone has modified the regulator
output.
Remove the ->volt_uV field and always rely on the PWM state to calculate
the regulator output.
Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com>
Reviewed-by: Brian Norris <briannorris@chromium.org>
Tested-by: Brian Norris <briannorris@chromium.org>
Tested-by: Heiko Stuebner <heiko@sntech.de>
Acked-by: Mark Brown <broonie@kernel.org>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
(cherry picked from commit
d9070fdbe40a04b61262bac0f7ff0c7c29a68015)
Change-Id: Iba7b143c1b08d547b5cd46ac42d9051fb34309df
Signed-off-by: David Wu <david.wu@rock-chips.com>