The MLB PLL clock's operation doesn't fit for clock framework and
it should be handled internally in MLB driver.
Remove initialization of pll8_mlb clock device but leave its
declaration in mx6q_clks to avoid affecting imx6q clock numbering.
Signed-off-by: Jiada Wang <jiada_wang@mentor.com>
CC: Dirk Behme <dirk.behme@de.bosch.com>
Signed-off-by: Shawn Guo <shawn.guo@linaro.org>
clk[pll5_video] = imx_clk_pllv3(IMX_PLLV3_AV, "pll5_video", "osc", base + 0xa0, 0x7f);
clk[pll6_enet] = imx_clk_pllv3(IMX_PLLV3_ENET, "pll6_enet", "osc", base + 0xe0, 0x3);
clk[pll7_usb_host] = imx_clk_pllv3(IMX_PLLV3_USB, "pll7_usb_host","osc", base + 0x20, 0x3);
clk[pll5_video] = imx_clk_pllv3(IMX_PLLV3_AV, "pll5_video", "osc", base + 0xa0, 0x7f);
clk[pll6_enet] = imx_clk_pllv3(IMX_PLLV3_ENET, "pll6_enet", "osc", base + 0xe0, 0x3);
clk[pll7_usb_host] = imx_clk_pllv3(IMX_PLLV3_USB, "pll7_usb_host","osc", base + 0x20, 0x3);
- clk[pll8_mlb] = imx_clk_pllv3(IMX_PLLV3_MLB, "pll8_mlb", "osc", base + 0xd0, 0x0);
/*
* Bit 20 is the reserved and read-only bit, we do this only for:
/*
* Bit 20 is the reserved and read-only bit, we do this only for: