unsigned BaseRegNo = BaseReg ? GetX86RegNum(Base) : -1U;
+ // 16-bit addressing forms of the ModR/M byte have a different encoding for
+ // the R/M field and are far more limited in which registers can be used.
+ if (Is16BitMemOperand(MI, Op)) {
+ if (BaseReg) {
+ // For 32-bit addressing, the row and column values in Table 2-2 are
+ // basically the same. It's AX/CX/DX/BX/SP/BP/SI/DI in that order, with
+ // some special cases. And GetX86RegNum reflects that numbering.
+ // For 16-bit addressing it's more fun, as shown in the SDM Vol 2A,
+ // Table 2-1 "16-Bit Addressing Forms with the ModR/M byte". We can only
+ // use SI/DI/BP/BX, which have "row" values 4-7 in no particular order,
+ // while values 0-3 indicate the allowed combinations (base+index) of
+ // those: 0 for BX+SI, 1 for BX+DI, 2 for BP+SI, 3 for BP+DI.
+ //
+ // R16Table[] is a lookup from the normal RegNo, to the row values from
+ // Table 2-1 for 16-bit addressing modes. Where zero means disallowed.
+ static const unsigned R16Table[] = { 0, 0, 0, 7, 0, 6, 4, 5 };
+ unsigned RMfield = R16Table[BaseRegNo];
+
+ assert(RMfield && "invalid 16-bit base register");
+
+ if (IndexReg.getReg()) {
+ unsigned IndexReg16 = R16Table[GetX86RegNum(IndexReg)];
+
+ assert(IndexReg16 && "invalid 16-bit index register");
+ // We must have one of SI/DI (4,5), and one of BP/BX (6,7).
+ assert(((IndexReg16 ^ RMfield) & 2) &&
+ "invalid 16-bit base/index register combination");
+ assert(Scale.getImm() == 1 &&
+ "invalid scale for 16-bit memory reference");
+
+ // Allow base/index to appear in either order (although GAS doesn't).
+ if (IndexReg16 & 2)
+ RMfield = (RMfield & 1) | ((7 - IndexReg16) << 1);
+ else
+ RMfield = (IndexReg16 & 1) | ((7 - RMfield) << 1);
+ }
+
+ if (Disp.isImm() && isDisp8(Disp.getImm())) {
+ if (Disp.getImm() == 0 && BaseRegNo != N86::EBP) {
+ // There is no displacement; just the register.
+ EmitByte(ModRMByte(0, RegOpcodeField, RMfield), CurByte, OS);
+ return;
+ }
+ // Use the [REG]+disp8 form, including for [BP] which cannot be encoded.
+ EmitByte(ModRMByte(1, RegOpcodeField, RMfield), CurByte, OS);
+ EmitImmediate(Disp, MI.getLoc(), 1, FK_Data_1, CurByte, OS, Fixups);
+ return;
+ }
+ // This is the [REG]+disp16 case.
+ EmitByte(ModRMByte(2, RegOpcodeField, RMfield), CurByte, OS);
+ } else {
+ // There is no BaseReg; this is the plain [disp16] case.
+ EmitByte(ModRMByte(0, RegOpcodeField, 6), CurByte, OS);
+ }
+
+ // Emit 16-bit displacement for plain disp16 or [REG]+disp16 cases.
+ EmitImmediate(Disp, MI.getLoc(), 2, FK_Data_2, CurByte, OS, Fixups);
+ return;
+ }
+
// Determine whether a SIB byte is needed.
// If no BaseReg, issue a RIP relative instruction only if the MCE can
// resolve addresses on-the-fly, otherwise use SIB (Intel Manual 2A, table
.code32
movb $0x0, (%si)
-// CHECK: encoding: [0x67,0xc6,0x06,0x00]
+// CHECK: encoding: [0x67,0xc6,0x04,0x00]
movb $0x0, (%esi)
// CHECK: encoding: [0xc6,0x06,0x00]
+ movw $0x1234, (%si)
+// CHECK: encoding: [0x67,0x66,0xc7,0x04,0x34,0x12]
+ movl $0x12345678, (%bx,%si,1)
+// CHECK: encoding: [0x67,0xc7,0x00,0x78,0x56,0x34,0x12]
+ movw $0x1234, 0x5678(%bp)
+// CHECK: encoding: [0x67,0x66,0xc7,0x86,0x78,0x56,0x34,0x12]