spi: sh-msiof: Avoid invalid clock generator parameters
authorGeert Uytterhoeven <geert+renesas@glider.be>
Fri, 5 Aug 2016 08:17:52 +0000 (10:17 +0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Fri, 7 Oct 2016 13:23:42 +0000 (15:23 +0200)
commit c3ccf357c3d75bd2924e049b6a991f7c0c111068 upstream.

The conversion from a look-up table to a calculation for clock generator
parameters forgot to take into account that BRDV x 1/1 is valid only if
BRPS is x 1/1 or x 1/2, leading to undefined behavior (e.g. arbitrary
clock rates).

This limitation is documented for the MSIOF module in all supported
SH/R-Mobile and R-Car Gen2/Gen3 ARM SoCs.

Tested on r8a7791/koelsch and r8a7795/salvator-x.

Fixes: 65d5665bb260b034 ("spi: sh-msiof: Update calculation of frequency dividing")
Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Signed-off-by: Mark Brown <broonie@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/spi/spi-sh-msiof.c

index a7934ab00b96505f3753fa38266238f3abcc6f64..d22de4c8c3995c87328f37fd140041833514a8bb 100644 (file)
@@ -263,6 +263,9 @@ static void sh_msiof_spi_set_clk_regs(struct sh_msiof_spi_priv *p,
 
        for (k = 0; k < ARRAY_SIZE(sh_msiof_spi_div_table); k++) {
                brps = DIV_ROUND_UP(div, sh_msiof_spi_div_table[k].div);
+               /* SCR_BRDV_DIV_1 is valid only if BRPS is x 1/1 or x 1/2 */
+               if (sh_msiof_spi_div_table[k].div == 1 && brps > 2)
+                       continue;
                if (brps <= 32) /* max of brdv is 32 */
                        break;
        }