This change replaces s3c-pl330.x clock device names with dma-pl330.x,
otherwise there won't be a correspondence between clock device name
and amba device name, thus clocks can't be enabled.
Fixes runtime errors on clk_get() from drivers/dma/pl330.c:
dma-pl330 dma-pl330.0: Cannot get operation clock.
dma-pl330: probe of dma-pl330.0 failed with error -22
Signed-off-by: Vladimir Zapolskiy <vz@mleia.com>
Acked-by: Boojin Kim <boojin.kim@samsung.com>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
static struct clk init_clocks_off[] = {
{
.name = "pdma",
- .devname = "s3c-pl330.0",
+ .devname = "dma-pl330.0",
.parent = &clk_hclk_psys.clk,
.enable = s5pv210_clk_ip0_ctrl,
.ctrlbit = (1 << 3),
}, {
.name = "pdma",
- .devname = "s3c-pl330.1",
+ .devname = "dma-pl330.1",
.parent = &clk_hclk_psys.clk,
.enable = s5pv210_clk_ip0_ctrl,
.ctrlbit = (1 << 4),