This change replaces s3c-pl330.x clock device names with dma-pl330.x,
otherwise there won't be a correspondence between clock device name
and amba device name, thus clocks can't be enabled.
Fixes runtime errors on clk_get() from drivers/dma/pl330.c:
dma-pl330 dma-pl330.0: Cannot get operation clock.
dma-pl330: probe of dma-pl330.0 failed with error -22
Signed-off-by: Vladimir Zapolskiy <vz@mleia.com>
Acked-by: Boojin Kim <boojin.kim@samsung.com>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
.ctrlbit = (1 << 10),
}, {
.name = "pdma",
- .devname = "s3c-pl330.0",
+ .devname = "dma-pl330.0",
.enable = exynos4_clk_ip_fsys_ctrl,
.ctrlbit = (1 << 0),
}, {
.name = "pdma",
- .devname = "s3c-pl330.1",
+ .devname = "dma-pl330.1",
.enable = exynos4_clk_ip_fsys_ctrl,
.ctrlbit = (1 << 1),
}, {