ARM: EXYNOS: Correct M-5MOLS sensor clock frequency on Universal C210 board
authorSylwester Nawrocki <s.nawrocki@samsung.com>
Tue, 31 Jan 2012 03:58:31 +0000 (12:58 +0900)
committerKukjin Kim <kgene.kim@samsung.com>
Tue, 31 Jan 2012 03:58:31 +0000 (12:58 +0900)
In order to keep the sensor's master clock frequency in valid range
when FIMC parent clock is xusbxti, the specified frequency must be
exactly 24MHZ, otherwise it's being set to too low value due to
rounding.

Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
arch/arm/mach-exynos/mach-universal_c210.c

index 37ac93e8d6d9ef44940dabb5f1d916301012ee54..0fc65ffde8ff7526f0f9362c8e18e3e27e3c6539 100644 (file)
@@ -910,7 +910,7 @@ static struct s5p_fimc_isp_info universal_camera_sensors[] = {
                .bus_type       = FIMC_MIPI_CSI2,
                .board_info     = &m5mols_board_info,
                .i2c_bus_num    = 0,
-               .clk_frequency  = 21600000UL,
+               .clk_frequency  = 24000000UL,
                .csi_data_align = 32,
        },
 };