rk3368: rk818 battery: allow capacity to be negative value
authorJianqun Xu <jay.xu@rock-chips.com>
Wed, 4 Mar 2015 09:58:53 +0000 (17:58 +0800)
committerJianqun Xu <jay.xu@rock-chips.com>
Wed, 4 Mar 2015 09:58:53 +0000 (17:58 +0800)
Signed-off-by: Jianqun Xu <jay.xu@rock-chips.com>
drivers/power/rk818_battery.c

index 1aa7c5a645a34dca2a5230cde23fc4da600547ab..26285db4e507ee0c477373f8f34274e1861d87d9 100644 (file)
@@ -2446,8 +2446,6 @@ static void update_battery_info(struct battery_info *di)
        di->remain_capacity = _get_realtime_capacity(di);
        if (di->remain_capacity > di->fcc)
                _capacity_init(di, di->fcc);
-       else if (di->remain_capacity < 0)
-               _capacity_init(di, 0);
 
        if (di->real_soc > 100)
                di->real_soc = 100;