given within a range of -127 to +255 degrees. Resolution depends on
temperature input and range.
-Each sensor has its own critical limit, but the hysteresis is common to all
-two channels.
+Each sensor has its own critical limit. Additionally, there is a relative
+hysteresis value common to both critical limits. To make life easier to
+user-space applications, two absolute values are exported, one for each
+channel, but these values are of course linked. Only the local hysteresis
+can be set from user-space, and the same delta applies to the remote
+hysteresis.
The lm95245 driver can change its update interval to a fixed set of values.
It will round up to the next selectable interval. See the datasheet for exact
static SENSOR_DEVICE_ATTR(temp2_input, S_IRUGO, show_input, NULL, 2);
static SENSOR_DEVICE_ATTR(temp2_crit, S_IWUSR | S_IRUGO, show_limit,
set_limit, 7);
-static SENSOR_DEVICE_ATTR(temp2_crit_hyst, S_IWUSR | S_IRUGO, show_crit_hyst,
- set_crit_hyst, 7);
+static SENSOR_DEVICE_ATTR(temp2_crit_hyst, S_IRUGO, show_crit_hyst, NULL, 7);
static SENSOR_DEVICE_ATTR(temp2_crit_alarm, S_IRUGO, show_alarm, NULL,
STATUS1_RTCRIT);
static SENSOR_DEVICE_ATTR(temp2_type, S_IWUSR | S_IRUGO, show_type,