When using PIO we have a timeout for the TX and RX FIFOs to ensure that
the data actually gets transferred. Warn if we hit that timeout - it
should never happen, but this makes sure we'll find out if it does.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Acked-by: Jassi Brar <jassi.brar@samsung.com>
Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
val = readl(regs + S3C64XX_SPI_STATUS);
} while (TX_FIFO_LVL(val, sci) && loops--);
+ if (loops == 0)
+ dev_warn(&sdd->pdev->dev, "Timed out flushing TX FIFO\n");
+
/* Flush RxFIFO*/
loops = msecs_to_loops(1);
do {
break;
} while (loops--);
+ if (loops == 0)
+ dev_warn(&sdd->pdev->dev, "Timed out flushing RX FIFO\n");
+
val = readl(regs + S3C64XX_SPI_CH_CFG);
val &= ~S3C64XX_SPI_CH_SW_RST;