For RoCE, resolution of layer 2 address attributes forces no VLAN if
link-local GIDs are used. This patch allows applications to choose
the VLAN ID for link-local based RoCE GIDs by setting IB_QP_VID in
their QP attribute mask, and prevents the core from overriding this
choice.
Cc: Ursula Braun <ursula.braun@de.ibm.com>
Signed-off-by: Moni Shoua <monis@mellanox.com>
Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com>
Signed-off-by: Roland Dreier <roland@purestorage.com>
if (rdma_link_local_addr((struct in6_addr *)qp_attr->ah_attr.grh.dgid.raw)) {
rdma_get_ll_mac((struct in6_addr *)qp_attr->ah_attr.grh.dgid.raw, qp_attr->ah_attr.dmac);
rdma_get_ll_mac((struct in6_addr *)sgid.raw, qp_attr->smac);
- qp_attr->vlan_id = rdma_get_vlan_id(&sgid);
+ if (!(*qp_attr_mask & IB_QP_VID))
+ qp_attr->vlan_id = rdma_get_vlan_id(&sgid);
} else {
ret = rdma_addr_find_dmac_by_grh(&sgid, &qp_attr->ah_attr.grh.dgid,
qp_attr->ah_attr.dmac, &qp_attr->vlan_id);