MT26468 (PCI ID 0x6764) devices can expose multiple physical
functions. The current driver only handles the primary physical
function. For other functions, the QUERY_FW firmware command will
fail with the CMD_STAT_MULTI_FUNC_REQ error code. Don't try to drive
such devices, but print a message saying the driver is skipping those
devices rather than just "QUERY_FW command failed."
Signed-off-by: Yevgeny Petrilin <yevgenyp@mellanox.co.il>
[ Rather than keeping unsupported devices bound to the driver, simply
print a more informative error message and exit - Roland ]
Signed-off-by: Roland Dreier <rolandd@cisco.com>
/* Bad management packet (silently discarded): */
CMD_STAT_BAD_PKT = 0x30,
/* More outstanding CQEs in CQ than new CQ size: */
- CMD_STAT_BAD_SIZE = 0x40
+ CMD_STAT_BAD_SIZE = 0x40,
+ /* Multi Function device support required: */
+ CMD_STAT_MULTI_FUNC_REQ = 0x50,
};
enum {
[CMD_STAT_LAM_NOT_PRE] = -EAGAIN,
[CMD_STAT_BAD_PKT] = -EINVAL,
[CMD_STAT_BAD_SIZE] = -ENOMEM,
+ [CMD_STAT_MULTI_FUNC_REQ] = -EACCES,
};
if (status >= ARRAY_SIZE(trans_table) ||
err = mlx4_QUERY_FW(dev);
if (err) {
- mlx4_err(dev, "QUERY_FW command failed, aborting.\n");
+ if (err == -EACCES)
+ mlx4_info(dev, "non-primary physical function, skipping.\n");
+ else
+ mlx4_err(dev, "QUERY_FW command failed, aborting.\n");
return err;
}