If the Designware core is configured with IC_EMPTYFIFO_HOLD_MASTER_EN
set to zero, allowing the TX FIFO to become empty causes a STOP
condition to be generated on the I2C bus. If the transmit FIFO
threshold is set too high, an erroneous STOP condition can be
generated on long transfers - particularly where the interrupt
latency is extended.
Signed-off-by: Andrew Jackson <Andrew.Jackson@arm.com>
Signed-off-by: Liviu Dudau <Liviu.Dudau@arm.com>
Tested-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
}
/* Configure Tx/Rx FIFO threshold levels */
- dw_writel(dev, dev->tx_fifo_depth - 1, DW_IC_TX_TL);
+ dw_writel(dev, dev->tx_fifo_depth / 2, DW_IC_TX_TL);
dw_writel(dev, 0, DW_IC_RX_TL);
/* configure the i2c master */