HID: hid-sensor-hub: fix report size
authorSrinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Sat, 26 Oct 2013 17:04:09 +0000 (10:04 -0700)
committerJiri Kosina <jkosina@suse.cz>
Wed, 30 Oct 2013 13:24:51 +0000 (14:24 +0100)
Most of the hid sensor field size is reported in report_size field
in the report descriptor. For rotation fusion sensor the quaternion
data is 16 byte field, the report size was set to 4 and report
count field is set to 4. So the total size is 16 bytes. But the current
driver has a bug and not taking account for report count field. This
causes user space to see only 4 bytes of data sent via IIO interface.
The number of bytes in a field needs to take account of report_count
field. Need to multiply report_size and report_count to get total
number of bytes.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
drivers/hid/hid-sensor-hub.c

index 10e1581022cfdea4acd4e5431ea43155e83898f0..9e4cdca549c00cb6a148cd8d60d37348a2ee0210 100644 (file)
@@ -326,7 +326,8 @@ int sensor_hub_input_get_attribute_info(struct hid_sensor_hub_device *hsdev,
                                field->logical == attr_usage_id) {
                                sensor_hub_fill_attr_info(info, i, report->id,
                                        field->unit, field->unit_exponent,
-                                       field->report_size);
+                                       field->report_size *
+                                                       field->report_count);
                                ret = 0;
                        } else {
                                for (j = 0; j < field->maxusage; ++j) {
@@ -338,7 +339,8 @@ int sensor_hub_input_get_attribute_info(struct hid_sensor_hub_device *hsdev,
                                                        i, report->id,
                                                        field->unit,
                                                        field->unit_exponent,
-                                                       field->report_size);
+                                                       field->report_size *
+                                                       field->report_count);
                                                ret = 0;
                                                break;
                                        }
@@ -425,9 +427,10 @@ static int sensor_hub_raw_event(struct hid_device *hdev,
                hid_dbg(hdev, "%d collection_index:%x hid:%x sz:%x\n",
                                i, report->field[i]->usage->collection_index,
                                report->field[i]->usage->hid,
-                               report->field[i]->report_size/8);
-
-               sz = report->field[i]->report_size/8;
+                               (report->field[i]->report_size *
+                                       report->field[i]->report_count)/8);
+               sz = (report->field[i]->report_size *
+                                       report->field[i]->report_count)/8;
                if (pdata->pending.status && pdata->pending.attr_usage_id ==
                                report->field[i]->usage->hid) {
                        hid_dbg(hdev, "data was pending ...\n");