UPSTREAM: regulator: pwm: Document pwm-dutycycle-unit and pwm-dutycycle-range
authorBoris Brezillon <boris.brezillon@free-electrons.com>
Tue, 14 Jun 2016 09:13:22 +0000 (11:13 +0200)
committerHuang, Tao <huangtao@rock-chips.com>
Mon, 6 Mar 2017 10:28:40 +0000 (18:28 +0800)
Document the pwm-dutycycle-unit and pwm-dutycycle-range properties.

Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com>
Acked-by: Brian Norris <briannorris@chromium.org>
Acked-by: Rob Herring <robh@kernel.org>
Acked-by: Mark Brown <broonie@kernel.org>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
(cherry picked from commit 58fd822b2e344edae6b4dbc09b19bd0c4a2f8f60)

Change-Id: I029307b54210f2203276a467e947d0fa2e51966d
Signed-off-by: David Wu <david.wu@rock-chips.com>
Documentation/devicetree/bindings/regulator/pwm-regulator.txt

index dd6f59cf1455ee9c629dd277d704469cf7cdad33..3aeba9f86ed8ee515dc8a169aafd65a0d4a777ba 100644 (file)
@@ -34,6 +34,18 @@ Only required for Voltage Table Mode:
                            First cell is voltage in microvolts (uV)
                            Second cell is duty-cycle in percent (%)
 
+Optional properties for Continuous mode:
+- pwm-dutycycle-unit:  Integer value encoding the duty cycle unit. If not
+                       defined, <100> is assumed, meaning that
+                       pwm-dutycycle-range contains values expressed in
+                       percent.
+
+- pwm-dutycycle-range: Should contain 2 entries. The first entry is encoding
+                       the dutycycle for regulator-min-microvolt and the
+                       second one the dutycycle for regulator-max-microvolt.
+                       Duty cycle values are expressed in pwm-dutycycle-unit.
+                       If not defined, <0 100> is assumed.
+
 NB: To be clear, if voltage-table is provided, then the device will be used
 in Voltage Table Mode.  If no voltage-table is provided, then the device will
 be used in Continuous Voltage Mode.
@@ -53,6 +65,13 @@ Continuous Voltage With Enable GPIO Example:
                regulator-min-microvolt = <1016000>;
                regulator-max-microvolt = <1114000>;
                regulator-name = "vdd_logic";
+               /* unit == per-mille */
+               pwm-dutycycle-unit = <1000>;
+               /*
+                * Inverted PWM logic, and the duty cycle range is limited
+                * to 30%-70%.
+                */
+               pwm-dutycycle-range <700 300>; /* */
        };
 
 Voltage Table Example: