From 16d9cfab930bb6f4946cff8ba7429701fd15b414 Mon Sep 17 00:00:00 2001 From: Eric Mei Date: Tue, 6 Jan 2015 09:35:02 -0800 Subject: [PATCH] raid5: check faulty flag for array status during recovery. When we have more than 1 drive failure, it's possible we start rebuild one drive while leaving another faulty drive in array. To determine whether array will be optimal after building, current code only check whether a drive is missing, which could potentially lead to data corruption. This patch is to add checking Faulty flag. Signed-off-by: NeilBrown --- drivers/md/raid5.c | 13 +++++++++---- 1 file changed, 9 insertions(+), 4 deletions(-) diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c index e75d48c0421a..cd2f96b2c572 100644 --- a/drivers/md/raid5.c +++ b/drivers/md/raid5.c @@ -5121,12 +5121,17 @@ static inline sector_t sync_request(struct mddev *mddev, sector_t sector_nr, int schedule_timeout_uninterruptible(1); } /* Need to check if array will still be degraded after recovery/resync - * We don't need to check the 'failed' flag as when that gets set, - * recovery aborts. + * Note in case of > 1 drive failures it's possible we're rebuilding + * one drive while leaving another faulty drive in array. */ - for (i = 0; i < conf->raid_disks; i++) - if (conf->disks[i].rdev == NULL) + rcu_read_lock(); + for (i = 0; i < conf->raid_disks; i++) { + struct md_rdev *rdev = ACCESS_ONCE(conf->disks[i].rdev); + + if (rdev == NULL || test_bit(Faulty, &rdev->flags)) still_degraded = 1; + } + rcu_read_unlock(); bitmap_start_sync(mddev->bitmap, sector_nr, &sync_blocks, still_degraded); -- 2.34.1