From 5689e830745b39dbab895e5e8df3f962cb7eecac Mon Sep 17 00:00:00 2001 From: Axel Lin Date: Mon, 25 Mar 2013 14:59:00 +0800 Subject: [PATCH] regulator: ab8500: Use regulator_list_voltage_linear for fixed voltage Both ab8500_regulator_mode_ops and ab8500_regulator_ops do not have volt_table setting, thus we can not use regulator_list_voltage_table for them. However, they have min_uV setting with n_voltages = 1, so use regulator_list_voltage_linear instead. Also remove setting set_voltage_time_sel for ab8500_regulator_mode_ops. It is used only for fixed voltage, so it does not need to implement set_voltage_time_sel. Signed-off-by: Axel Lin Acked-by: Lee Jones Signed-off-by: Mark Brown --- drivers/regulator/ab8500.c | 5 ++--- 1 file changed, 2 insertions(+), 3 deletions(-) diff --git a/drivers/regulator/ab8500.c b/drivers/regulator/ab8500.c index a2d19c650f24..12e274039ae1 100644 --- a/drivers/regulator/ab8500.c +++ b/drivers/regulator/ab8500.c @@ -363,8 +363,7 @@ static struct regulator_ops ab8500_regulator_mode_ops = { .set_mode = ab8500_regulator_set_mode, .get_mode = ab8500_regulator_get_mode, .get_voltage_sel = ab8500_regulator_get_voltage_sel, - .list_voltage = regulator_list_voltage_table, - .set_voltage_time_sel = ab8500_regulator_set_voltage_time_sel, + .list_voltage = regulator_list_voltage_linear, }; static struct regulator_ops ab8500_regulator_ops = { @@ -372,7 +371,7 @@ static struct regulator_ops ab8500_regulator_ops = { .disable = ab8500_regulator_disable, .is_enabled = ab8500_regulator_is_enabled, .get_voltage_sel = ab8500_regulator_get_voltage_sel, - .list_voltage = regulator_list_voltage_table, + .list_voltage = regulator_list_voltage_linear, }; static struct ab8500_regulator_info -- 2.34.1